TDS3000C Digital Phosphor Oscilloscope

TDS3000C Digital Phosphor Oscilloscope

With up to 500 MHz bandwidth and 5 GS/s sample rate, the TDS3000C Oscilloscope Series provides you with the performance to visualize fast-changing signals in a compact, battery-capable design. With dedicated front-panel controls and 25 automatic measurements, the TDS3000C Series is easy to use so you spend less time re-learning how to use your oscilloscope and more time on the task at hand.

Bandwidth

Up to 500 MHz

Analog Channels

2 or 4

Record Length

10k points

Sample Rate

Up to 5 GS/s

 

Features

Benefits

Digital real-time sampling Accurately capture signals with at least 5x oversampling.
Digital phosphor display Quickly capture and visualize glitches and infrequent events with a high waveform capture rate and intensity-graded display.
Advanced triggering Capture digital signal anomalies with runt, glitch, rise/fall-time, and setup/hold violation triggers.
Dedicated front-panel controls Spend less time learning and more time on the task at hand with front-panel controls.
Front-panel USB host port Quickly store and transfer your waveforms.
PC connectivity Simply transfer, analyze and document results with NI LabVIEW SignalExpress™ TE and Tektronix OpenChoice® Desktop software.
Just 5.9 inches (149 mm) deep Free up valuable bench space.
Battery pack (optional) Work where you need to with up to three hours of portable battery operation.
Application modules (optional) Transform your oscilloscope into a specialized instrument for limit testing, telecom mask testing, and video troubleshooting.

 

Models

Model Analog Bandwidth Sample Rate Record Length Analog Channels List Price
TDS3012C 100 MHz 1.25 GS/s 10 Kpoints 2 Configure & Quote
TDS3014C 100 MHz 1.25 GS/s 10 Kpoints 4 Configure & Quote
TDS3032C 300 MHz 2.5 GS/s 10 Kpoints 2 Configure & Quote
TDS3034C 300 MHz 2.5 GS/s 10 Kpoints 4 Configure & Quote
TDS3052C 500 MHz 5 GS/s 10 Kpoints 2 Configure & Quote
TDS3054C 500 MHz 5 GS/s 10 Kpoints 4 Configure & Quote
ModelTDS3012C
Analog BandwidthSample RateRecord Length
100 MHz1.25 GS/s10 Kpoints
Analog Channels
2
ModelTDS3014C
Analog BandwidthSample RateRecord Length
100 MHz1.25 GS/s10 Kpoints
Analog Channels
4
ModelTDS3032C
Analog BandwidthSample RateRecord Length
300 MHz2.5 GS/s10 Kpoints
Analog Channels
2
ModelTDS3034C
Analog BandwidthSample RateRecord Length
300 MHz2.5 GS/s10 Kpoints
Analog Channels
4
ModelTDS3052C
Analog BandwidthSample RateRecord Length
500 MHz5 GS/s10 Kpoints
Analog Channels
2
ModelTDS3054C
Analog BandwidthSample RateRecord Length
500 MHz5 GS/s10 Kpoints
Analog Channels
4
Model Analog Bandwidth Sample Rate Record Length Analog Channels List Price
TDS3012C 100 MHz 1.25 GS/s 10 Kpoints 2 Configure & Quote
TDS3014C 100 MHz 1.25 GS/s 10 Kpoints 4 Configure & Quote
TDS3032C 300 MHz 2.5 GS/s 10 Kpoints 2 Configure & Quote
TDS3034C 300 MHz 2.5 GS/s 10 Kpoints 4 Configure & Quote
TDS3052C 500 MHz 5 GS/s 10 Kpoints 2 Configure & Quote
TDS3054C 500 MHz 5 GS/s 10 Kpoints 4 Configure & Quote
ModelTDS3012C
Analog BandwidthSample RateRecord Length
100 MHz1.25 GS/s10 Kpoints
Analog Channels
2
ModelTDS3014C
Analog BandwidthSample RateRecord Length
100 MHz1.25 GS/s10 Kpoints
Analog Channels
4
ModelTDS3032C
Analog BandwidthSample RateRecord Length
300 MHz2.5 GS/s10 Kpoints
Analog Channels
2
ModelTDS3034C
Analog BandwidthSample RateRecord Length
300 MHz2.5 GS/s10 Kpoints
Analog Channels
4
ModelTDS3052C
Analog BandwidthSample RateRecord Length
500 MHz5 GS/s10 Kpoints
Analog Channels
2
ModelTDS3054C
Analog BandwidthSample RateRecord Length
500 MHz5 GS/s10 Kpoints
Analog Channels
4
Data SheetSoftware Package / Software OptionDescriptionConfigure and Quote
TDS3AAM Application Module: Advanced Analysis Configure & Quote
TDS3LIM Application Module: Limit Testing Configure & Quote
TDS3TMT Application Module: Telecom Mask Testing Configure & Quote
TDS3VID Application Module: HDTV and Custom Video Triggering Configure & Quote
High Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
P5205A

High Voltage Probe: 100 MHz, 50X/500X, 1.3 kV, Differential, BNC

Configure & Quote
P5210A High Voltage Probe: 50 MHz, 100X/1000X, 5.6 kV, Differential, BNC Configure & Quote
Passive Probe
Datasheet LinkProbeDescriptionConfigure and Quote
P6139B

Passive Probe: 500 MHz, 10X, BNC

Configure & Quote
Low Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
P6243 Active Probe: 1 GHz, 10X, Single-ended, TekProbe Configure & Quote
Current Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TCP202A

Probe, AC/DC Current; DC coupled, 15 Amp Max DC; 50 MHz BW, TekProbe Lvl2 Interface; Certificate of Traceable Calibration Standard

Configure & Quote
Data SheetAccessoryDescription
1103 TekProbe Power Supply
AC3000 Soft Carrying Case
HCTEK4321 Hard Carrying Case
TDS3BATC Battery Pack for TDS3000 Series Oscilloscopes
TDS3GV MODULE; COMMUNICATION MODULE, GPIB, VGA, RS-232
TitleTypeDate
Difference between Position and Offset on an oscilloscope
To answer this first you need to understand the layout of how your waveform trace is displayed. On your oscilloscope you generally will see either 8 or 10 divisions vertically on the screen. Along the left side of the screen you will see a marker…
FAQ ID: 247211 16 Jan 2018
TEKVISA CONNECTIVITY SOFTWARE, V4.0.4

Part number: 066093809
Utility 12 Jan 2018
How do connect my Color Difference Component Analog Video signals to the TDS3000/B Scope with TDS3VID or TDS3SDI Video module to get a Vectorscope display?
Please refer to the Hook-up document links below for connection descriptions, and to the Module User Manuals for Quick Menu setup details. TDS3VID Hookups (7Kb) TDS3SDI Hookups With Serial Digital Video (7Kb) TDS3SDI Hookups With Non-Serial Video (…
FAQ ID: 58251 29 Dec 2017
10 Factors in Choosing a Basic Oscilloscope

Basic oscilloscopes are used as windows into signals for troubleshooting circuits or checking signal quality. They generally come with bandwidths from around 50 MHz to 200 MHz and are found in almost every design lab, education lab, service center…
Literature number: 3GW_60848_1
Brochure 28 Nov 2017
Tektronix Toolbars for Microsoft Office, V4.0.4

Tektronix Toolbars for Microsoft Office, V4.0.4
Part number: 066133202
Utility 30 Oct 2017
XYZs of Oscilloscopes Primer

After reading this primer, you will be able to: Describe how oscilloscopes work, Describe the differences between analog, digital storage, digital phosphor, and digital sampling oscilloscopes, describe electrical waveform types, understand basic…
Literature number: 03T-8605-7
Primer 09 Oct 2017
TEKVISA CONNECTIVITY SOFTWARE - V4.1.1

Part number: 066093811
Application 29 Sep 2017
How do I connect to an Oscilloscope over Ethernet with TekVISA?
Please download the following document.
FAQ ID: 63521 27 Sep 2017
How do I connect my TDS3000B/TDS3000C Series oscilloscope to a network printer?
First be sure the oscilloscope is on the LAN, then go to the oscilloscope's Utility/System/Hardcopy menu and select the Format appropriate to your network printer (For example the Lexmark Optra Lxi is a postscript printer, so a user of that printer would…
FAQ ID: 60686 26 Sep 2017
What is TekVISA and how can I use it to communicate with and control my instrument?
VISA is an acronym that stands for Virtual Instrument Software Architecture. In a nutshell, VISA handles the communications between your computer’s OS and the instrument.  You may be familiar with TekVISA, which is Tektronix’s own brand of VISA. Agilent…
FAQ ID: 69176 26 Sep 2017
Downloads
Download

Download Manuals, Datasheets, Software and more:

Go to top