The MSO/DPO2000B Mixed Signal Oscilloscope series is the most powerful scope in its class with advanced debug features at an entry-level price. With as many as 20 channels, you can analyze analog and digital signals with a single instrument. Combine that with automated serial and parallel bus analysis and innovative Wave Inspector® controls, you get the tools you need to speed up your debugging. See all oscilloscopes »

Every engineer has a scope story
Share your #TekScopeStory and be
part of the #TekOneMillion.

Base Price
US $1,490 - US $4,050
Buy/Quote Questions? Chat Now
Bandwidth

Up to 200 MHz

Record Length

1 Mpoints

Analog channels

2 or 4

Sample Rate

1 GS/s on all channels

 

Find, Debug and Analyze Faster

Thumbnail

Look at many points in your design with 4 analog and 16 digital channels plus 2 bus waveforms. Find anomalies fast with digital phosphor display and 125 trigger combinations, and use Wave Inspector to pan through 1M waveform points, zoom in, mark points of interest, and navigate from mark to mark. Plus: FilterVu reduces noise, not glitches.

Forget About Manually Decoding Serial Buses

Thumbnail

Reduce errors and save time with automatic serial bus decoding. Plus, optional serial triggering and decoding modules automate triggering on specific packet content, then displays data in analog waveforms and bus views for quick insights.  Also available: options for the leading serial buses in automotive, embedded design and computer applications.

A Probe Interface that Broadens the Possibilities

Thumbnail

The Tek VPI probe interface provides wide application coverage and you don't have to worry about scale factors. Use a wide range of active and current probes that automatically communicate scale factors, enable simple deskewing and provide probe information on the scope display.

Simplify Mixed Signal Debugging

Thumbnail

Debug mixed signal designs with up to 4 analog and 16 digital channels, all time-correlated. Combine digital channels to show parallel buses or decode serial buses. Add in the innovative P6316 logic probe to make it easy to connect to your design and keep track of the signals.

Highlights

  • 16 fully integrated channels, all with 1GS/s sampling rate.
  • Easy to use logic analyzer functionality.
  • Define parallel or serial buses for triggering and decoding.
  • Simple visualization with waveform grouping and color coding.

 

Model Analog Bandwidth Sample Rate Record Length Analog Channels Digital Channels List Price
DPO2002B 70 MHz 1 GS/s 1 Mpoints 2 - US $1,490
Configure & Quote
DPO2012B 100 MHz 1 GS/s 1 Mpoints 2 - US $1,860
Configure & Quote
DPO2004B 70 MHz 1 GS/s 1 Mpoints 4 - US $2,270
Configure & Quote
MSO2002B 70 MHz 1 GS/s 1 Mpoints 2 16 US $2,320
Configure & Quote
DPO2022B 200 MHz 1 GS/s 1 Mpoints 2 - US $2,620
Configure & Quote
DPO2014B 100 MHz 1 GS/s 1 Mpoints 4 - US $2,690
Configure & Quote
MSO2012B 100 MHz 1 GS/s 1 Mpoints 2 16 US $2,690
Configure & Quote
MSO2004B 70 MHz 1 GS/s 1 Mpoints 4 16 US $3,090
Configure & Quote
DPO2024B 200 MHz 1 GS/s 1 Mpoints 4 - US $3,230
Configure & Quote
MSO2022B 200 MHz 1 GS/s 1 Mpoints 2 16 US $3,450
Configure & Quote
MSO2014B 100 MHz 1 GS/s 1 Mpoints 4 16 US $3,500
Configure & Quote
MSO2024B 200 MHz 1 GS/s 1 Mpoints 4 16 US $4,050
Configure & Quote
Model Analog Bandwidth Sample Rate Record Length Analog Channels Digital Channels List Price
DPO2002B 70 MHz 1 GS/s 1 Mpoints 2 - US $1,490
Configure & Quote
DPO2012B 100 MHz 1 GS/s 1 Mpoints 2 - US $1,860
Configure & Quote
DPO2004B 70 MHz 1 GS/s 1 Mpoints 4 - US $2,270
Configure & Quote
MSO2002B 70 MHz 1 GS/s 1 Mpoints 2 16 US $2,320
Configure & Quote
DPO2022B 200 MHz 1 GS/s 1 Mpoints 2 - US $2,620
Configure & Quote
DPO2014B 100 MHz 1 GS/s 1 Mpoints 4 - US $2,690
Configure & Quote
MSO2012B 100 MHz 1 GS/s 1 Mpoints 2 16 US $2,690
Configure & Quote
MSO2004B 70 MHz 1 GS/s 1 Mpoints 4 16 US $3,090
Configure & Quote
DPO2024B 200 MHz 1 GS/s 1 Mpoints 4 - US $3,230
Configure & Quote
MSO2022B 200 MHz 1 GS/s 1 Mpoints 2 16 US $3,450
Configure & Quote
MSO2014B 100 MHz 1 GS/s 1 Mpoints 4 16 US $3,500
Configure & Quote
MSO2024B 200 MHz 1 GS/s 1 Mpoints 4 16 US $4,050
Configure & Quote
Data Sheet Software Package / Software Option Description Configure and Quote
View Datasheet Data Sheet Module Description
View Datasheet DPO2CONN Communication I/O Module: Ethernet and External Monitor Out Description
The MSO2000B Series offers the best debugging capability on the highest usable number of channels in its class.
2m 14s
Debugging Serial Buses in Embedded System Designs
Learn the basics of the hardware protocols of the most common serial buses, such as I2C, SPI , USB, RS-232/422/485/UART, CAN, CAN FD, LIN, FlexRay, Ethernet, and I2S/LJ/RJ/TDM.  Find out how to use the protocol trigger, decode and search capabilities …

Literature Number: 48W-19040-21
Application Note
How to Use a Mixed Signal Oscilloscope to Test Digital Circuits
Learn how to set up a mixed signal oscilloscope and how use it in several applications including: triggering on pulse width violations, combining analog and digital waveforms to capture crosstalk, troubleshooting setup/hold violations, and checking …

Literature Number: 3GT-24008-4
Application Note
How do I set up a I2C Bus Decode?
The procedure to set up a I2C bus decode and trigger is simple once you understand the basics. First you have to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the DAC as possible with good …
Faq Id64756
I downloaded and Installed OpenChoice Desktop, but it doesn't recognize my scope.
Refer to the Prerequisites.txt file available to download on the same page for OpenChoice desktop. Make sure you have all the prerequisites specified.    Prerequisites 1. PC equipped with  Microsoft Windows 7 32 Bit and 64 Bit OS, Windows 8.1 32 Bit …
Faq Id474266
Where is the "Invert" button on my DPO2000 or the MSO2000?
If you have older firmware version v1.06 or below, you will need to use the Math function on the oscilloscope to subtract the channel of interest from another channel that is set to ground coupling in order to get the invert function.The invert …
Faq Id60221
How do I use the programmer manual for my instrument?
TekVISA Download Link: TEKVISA CONNECTIVITY SOFTWARE Hello and welcome to Tektronix, today I’m presenting the last part in the 3-part series on using TekVISA. I’ll be giving a basic overview of programmer manuals and how to use them to find the …
Faq Id69186
Are MSO2000 and DPO2000 Series application modules compatible with MSO4000+ DPO4000+ MSO3000+ or DPO3000 Series oscilloscopes? Are MSO3000 and DPO3000 Series application modules compatible with MSO4000+ DPO4000+ MSO2000+ or DPO2000 Series oscilloscopes? Are MSO4000 and DPO4000 Series application modules compatible with MSO3000+ DPO3000+ MSO2000+ or DPO2000 Series oscilloscopes?
No.  Application modules are unique for each oscilloscope series, and cannot be used in other series oscilloscopes. They can be moved between oscilloscopes in the same series.
Faq Id60351
What are the differences for the MSO/DPO2000 and MSO/DPO2000B series?
The differences are that the MSO/DPO2000B offer the 70MHz models and a standard 5 years warranty instead of the 3 years warranty.
Faq Id64811
What are some of the benefits of the TekVPI probe interface?
The biggest benefits of the TekVPI™ probe interface are versatility and ease of use. Oscilloscopes with TekVPI interface support a wide range of probes including TekVPI probes, BNC and TekProbe-BNC Level 1 probes, and TekProbe-BNC Level 2 probes …
Faq Id56016
How do I utilize the measurement features on a DPO/MSO/MDO3000 and DPO/MSO/MDO4000 Series oscilloscope?
The Measurements are the same as the DPO/MSO2000 Series scopes. By going into the measurement menu you can add and remove up to 4 measurements. You can gate the measurements which allows you to only measure the part of the captured waveform that you …
Faq Id64651
How do I download and install the 30-day trial version of NI LabVIEW SignalExpress Tektronix Edition?
Note: NI LabVIEW SignalExpress Tektronix Edition is no longer offered by Tektronix. This FAQ is "historical only".National Instruments SignalExpress Tektronix Edition is a measurement automation tool that allows SignalExpress to control a Tektronix …
Faq Id66221
How do I run a Signal Path Compensation (SPC) on an DPO/MSO/MDO4000 Series oscilloscope?
Signal Path Compensation (SPC) should be run anytime you are getting DC offsets in your signals, or your scope has moved locations and might have changed temperature, or if it's been more then a month since your last SPC. This is a standard procedure …
Faq Id64681
What is aliasing and how do I detect it and fix it on my oscilloscope?
Aliasing is basically a form of under sampling and what is displayed on the scopes is an indistinguishable waveform. The under sampled waveform is then contstructed to look like a slower frequency waveform or a flat line in the case of the sample …
Faq Id64691
What does USBTMC mean?
USBTMC stands for USBTest and Measurement Class and allows GPIB-style communication over USB using USBTMC-compliant VISA layers.
Faq Id56056
Programing - How do I get a Screen Capture from DPO4000 scope using Python?
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …
Faq Id64791
How Do I Set Up a Parallel Bus Decode?
For doing Parallel Bus decode Tektronix recommends using a MSO or MDO + MSO option Series oscilloscopes. This feature comes standard in the Bus menu and can be used in a variety of ways. Start by turning it on, selecting the channel and setting your …
Faq Id64771
Does the MSO4000+ MSO3000+ or MSO2000 series support the TLAHRA high impedance probe adapter?
This accessory is compatible with the P6516 and P6316 logic probes.
Faq Id61681
Why does the Tkdpo2k3k4k_ReadWaveform() function in the Tkdpo2k3k4k IVI-C driver time out every time I call it when I am connected to the instrument via Ethernet? The function call works fine over USB, but over Ethernet it always times out.
The Tkdpo2k3k4k_ReadWaveform() function makes use of the Service Request Event in VISA so the scope can notify the driver when it has completed its acquisition and the waveform data is ready to be fetched as opposed to the driver polling the scope …
Faq Id72221
Is there a mictor adapter for the P6616 (logic probe for MSO5000B, MSO4000B, and MDO4000C + MDO4MSO) or P6516 (logic probe for the MSO4000 Series) or the P6316 (logic probe for MSO2000, MSO3000, MDO3000 + MDO3MSO Series)?
A mictor adapter is available from our partner Nexus Technologies. Use the mictor adapter NEX-HD2HEADER http://www.nexustechnology.com/products/laAccessories/hd2header/  
Faq Id59716
How do I set up a CAN bus decode?
Depending on what scope you have will depend on what options are availiable for decoding your CAN signal. For all the DPO/MSO2000/3000/4000/5000 and MDO3000/4000 Series scopes there are modules or license keys that can be purchased. Once you have one …
Faq Id64751
When should I run SPC?
Signal Path Compensation (SPC) can be run at any time. The best times to run SPC are: After the oscilloscope has been powered on and has warmed up for 20 minutes or more. If the temperature has changed more than 5 degrees C since the last SPC was …
Faq Id60156
What cart does my scope use?
Below are the Instrument Carts that can be purchased from Tektronix.                                         K4000                                                                             K420                              K475 More information can …
Faq Id64561
What is the difference between the DPO/MSO2000 and DPO/MSO2000B?
Features that were added in the B models of the scopes are a price reduction, the addition of four 70 MHz models and two 2-channel 200 MHz models, and the extension of the warranty to 5 years.
Faq Id66186
Is the .ISF waveform file format file used on the DPO2000+ MSO2000+ DPO3000+ MSO3000+ DPO4000 and MSO4000 series compatible with the TDS3000/TDS3000B/TDS3000C format files?
No.   The formats are very similar, but they are not compatible.
Faq Id63781
How do I use the Save and Recall functionality of the MDO4000 series oscilloscope?
To save a screen image, go to the Save/Recall menu at the bottom of the scope. From there select the Save Screen Image softkey. This will pop up a new window with saving options. Saving a screen image requires an external memory device, such as a USB …
Faq Id69156
How do I erase and declassify an MSO/DPO2000, MSO/DPO/MDO3000, and MSO/DPO/MDO4000 Series oscilloscope?
This example will show you how to declassify the MDO4000/B/C Series oscilloscope. This procedure also applies to the MSO/DPO4000/B, MSO/DPO/MDO3000, and the MSO/DPO2000/B series of oscilloscope.The first step in the declassification process is …
Faq Id66231
What is the difference between Position and Offset on an oscilloscope?
To answer this first you need to understand the layout of how your waveform trace is displayed. On your oscilloscope you generally will see either 8 or 10 divisions vertically on the screen. Along the left side of the screen you will see a marker …
Faq Id247211
How can I change the TekVISA Instrument descriptor “device name” used to identify the oscilloscopes to which I routinely connect?
Open TekVISA V4.0.0+ OpenChoice Instrument Manager by selecting Start -> All Programs -> TekVISA ->  OpenChoice Instrument Manager.Select (highlight) the Instrument descriptor listed in the Instruments list for the connected Oscilloscope.Click the …
Faq Id66181
What rackmount does my scope use?
Oscilloscope Family Rackmount TDS1000/TDS2000 RM2000 TDS1000B/TDS2000B/TDS2000C RM2000B TPS2000/TPS2000B No Rackmount - Strap hanger 343-1689 …
Faq Id64571
How do I send an oscilloscope BUS event table file to my PC?
Use the following commands:SAVe:EVENTtable:BUS (stores Bus Event table on the oscilloscope mass storage; CompactFlash card, USB flash drive)FILESystem:READFile (transfers stored Bus Event table file over the connection to the …
Faq Id59471
Can my oscilloscope operate on 400Hz power?
Most scopes have a wide range of operating voltages and frequencies, a full list can be found in the user manual of your specific oscilloscope. If you're having trouble finding your answer or can't find the manual, please call our Technical Support …
Faq Id63266
My Tektronix oscilloscope uses the Linux operating system.  Where do I get a copy of the linux open source code as stated in the GNU Lesser General Public License notice?
For our Linux based instruments or programs licensed under the “GNU General Public License (GPL) or Lesser GNU General Public License (LGPL)” the complete corresponding sources are available. You can order a complete machine-readable copy of the …
Faq Id64866
How do I order the DPO Demo 2 board and the USB cable (020-2924-XX) used in the DPO2000/MSO2000+ DPO3000/MSO3000 and DPO2000/MSO4000 Series Lab Exercise Book?
Email the request with part number (020-2924-xx) to [email protected] or call 1-800-833-9200 prompt 1 for sales.
Faq Id59461
How do I set up a RS232 bus decode?
The procedure to set up a RS232 bus decode and trigger is simple once you understand the basics. First you need to have the correct module or scope option. Second make sure your signal is on screen and taking up as much of the screen as possible with …
Faq Id64761
Do I need a TekVPI power adapter part number 119-8726-00 (previous p/n was 119-7465-xx) for each probe I connect to my DPO2000/B and MSO2000/B series oscilloscope? How does the power adapter connect the oscilloscope?
No. Only 1 power adapter is needed per oscilloscope.  The power adapter provides 50 W of power which is sufficient to support any combination of compatible probes used on channels 1, 2, 3, 4 and aux in. To connect the TekVPI power adapter, simply …
Faq Id59221
What communication modules can I use with my oscilloscope?
Please go to the "Supported Data Interfaces" section of www.tek.com/products/oscilloscopes/supported_printers.pdf.
Faq Id64051
Are the DPO2AUTO+ DPO2COMP+ and DPO2EMBD Application Modules licensed to a specific MSO2000 or DPO2000 Series oscilloscope serial number? Are the DPO3AERO+ DPO3AUDIO+ DPO3AUTO+ DPO3COMP+ DPO3EMBD+ DPO3FLEX+ DPO3PWR+ and DPO3VID Application Modules licensed to a specific MSO3000 or DPO3000 Series oscilloscope serial number? Are the DPO4AERO+ DPO4AUDIO+ DPO4AUTO+ DPO4AUTOMAX+ DPO4COMP+ DPO4EMBD+ DPO4ENET+ DPO4USB+ DPO4LMT+ DPO4PWR+ MDO4TRIG+ and DPO4VID Application Modules licensed to a specific MDO4000, MSO4000 or DPO4000 Series oscilloscope serial number?
The application modules are not licensed to a specific oscilloscope serial number and can be swapped between the various models within the oscilloscope series.
Faq Id55201
Why does the DPO2000 or MSO2000 series oscilloscope sometimes present the record length selections as 100k and 1.00M but other times it presents 125k and 1.25M+ or 125k and 1.00M?
Here are the rules to understand when a record length is available:For the "short" record lengths: 100k record lengths: Time/Div <= 40us (40 us/div and faster) 125k record lengths: Time/Div >= 100us (100 us/div and slower)For the "long" record …
Faq Id60256
What is TekVISA and how can I use it to communicate with and control my instrument?
VISA is an acronym that stands for Virtual Instrument Software Architecture. In a nutshell, VISA handles the communications between your computer’s OS and the instrument.  You may be familiar with TekVISA, which is Tektronix’s own brand of VISA …
Faq Id69176
How can I disable "Autoset" on the DPO2000+ MSO2000+ DPO3000+ MSO3000+ DPO4000 or MSO4000 series oscilloscope?
1. Press and hold Autoset.2. Press and hold Menu Off.3. Release Menu Off, and then release Autoset.This will open the Autoset menu options.  You may now select either Enable or Disable. 
Faq Id59391
I have captured waveform data as .isf files. I want to know which software can convert .isf to .png or .jpg.
If the .isf file was captured on the DPO2000/MSO2000, DPO3000/MSO3000, DPO4000/MSO4000 series scope, you could open it with OpenChoice Desktop software. Or you could recall the waveform into the scope as a reference waveform, and then save on the …
Faq Id61871
Does NI LabVIEW SignalExpress Tektronix Edition version 2.51 work with the MSO2000+ DPO2000+ MSO3000+ DPO3000+ MSO4000+ and DPO4000 Series oscilloscopes?
NI LabVIEW SignalExpress TE does work with the MSO/DPO series, with two main caveats:NI SignalExpress TE only acquires the analog channel data, not the digital channels or bus waveforms.The step used for the MSO3000 is the same step used for the …
Faq Id63376
What is the maximum bit rate a decoded SPI bus can trigger on?
Different oscilloscopes have different triggering circuitry therefor the limits of what speeds can be achieved vary by scope. Please use the following table to easily look up your scope and determine your max SPI bus trigger level.  For more …
Faq Id62256
Will the probes I currently own work with on a DPO2000 (or MSO2000) series oscilloscope?
Use the Oscilloscope Probe & Accessory Selector Tool, available on www.tek.com, to determine if your probe is compatible with the DPO2000 (or MSO 2000) series oscilloscope.  After you have the tool open, under the “select by instrument series” …
Faq Id60316
How do I Set Up a LIN serial Bus decode?
For doing Local Interconnect Network (LIN) bus decode Tektronix recommends using a DPO/MSO/MDO series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus channel …
Faq Id64781
What are the maximum power draw ratings for the DPO2000/B and MSO2000/B series oscilloscopes+ TEKVPI probes+ and TPA-BNC adapter?
Please see the table link below
Faq Id59896
How do I reduce noise on signals using an oscilloscope?
There are many methods to reduce many types of noise on a signal. Tektronix oscilloscopes can do this through bandwidth limiting the scope input, averaging your signal, changing the sampling method to hi-resolution mode, and more. This video …
Faq Id64706
The data sheet for my oscilloscope says that the vertical input sensitivity is 1 mV/div to 10 V/div in 1 MΩ mode. But I turn the Vertical Scale control fully clockwise and I can only get down to 10 mV/div. What am I doing wrong?
You probably aren't doing anything wrong. But you do have a 10X probe attached to that channel, right? The 1 mV/div specs relate to the oscilloscope inputs. If the signal’s source impedance is relatively low (<< 1 MOhm), the signal’s frequency is …
Faq Id58571
How do I clear my memory using TekSecure on a MSO/DPO/MDO4000 Series oscilloscope?
This procedure for clearing the memory on oscilloscope can be applied to the DPO/MSO/MDO4000, DPO/MSO3000 and DPO/MSO2000 Series oscilloscope families. By clearing the memory you will lose all saved reference waveforms, saved setups and all other …
Faq Id64686
Are LabView drivers available for the DPO2000+ MSO2000+ DPO3000+ MSO3000+DPO4000+ and MSO4000 series oscilloscopes?
A. IVI drivers to support LabView, LabWindows/CVI, and LabView SignalExpress can be found on the National Instrument website. Go to www.ni.com, search on "instrument drivers", and then search by specific model number.The MSO4000, DPO4000, MSO3000 …
Faq Id60341
How do I save and load a reference waveform to a DPO/MSO3000 series oscilloscope?
This Video will explain how to setup, save and load a reference waveform. It can be done through a USB flash drive or by internal memory. This method for using reference waveforms can be applied to all MSO/DPO2000, MSO/DPO3000, MSO/DPO/MDO4000 …
Faq Id64641
When running SPC (signal path compensation) on my oscilloscope, I get the message that SPC failed.  What does failing SPC indicate?
When an oscilloscope says SPC failed, 99.9 percent of the time it is a hardware failure that will need repair.  A few things you can do before sending in for repair: Make sure all inputs (probes and cables) are removed from all the channel inputs …
Faq Id59621
What is SPC?
SPC is the acronym for Signal Path Compensation. SPC's.  Running Signal Path Compensation corrects for DC inaccuracies caused by temperature variations and/or long-term drift. The benefit of running SPC is that is optimizes the oscilloscope's …
Faq Id60041
Companies such as National Instruments and LeCroy sell USB-to-GPIB adapters. How do their adapters compare to the TEK-USB-488?
The products from National Instruments (GPIB-USB-B or GPIB-USB-HS) and LeCroy (WS-GPIB) are USB host to GPIB device adapter. These would be used for instruments that have a GPIB interface with controllers that have a USB port. The TEK-USB-488 was …
Faq Id56456
Why do I see 16 flat lines for the MSO digital logic inputs when the same signals are displayed properly on the analog channels and all channels are setup for valid trigger threshold levels?
A common mistake for some, we first recommend verifing that the front panel MSO digital probe is properly connected by squeezing the probe's side latch buttons to un-plug, remove the probe then re-insert the probe label side up into the front panel …
Faq Id60251
Why Should My Signal Fit Within The Screen Of My Tektronix Oscilloscope?
Scaling your signal to fit within the screen will remove signal distortion caused by clipping. Clipping is caused by exceeding the limits of the instrument's input. Tektronix's digital oscilloscopes are designed such that each division is 25 digital …
Faq Id60306
How do I use TekVISA to send commands to my instrument?
TekVISA Download Link:TEKVISA CONNECTIVITY SOFTWARE In order to communicate with and control the scope, you can use OpenChoice Talker-Listener. Back on the Application and Utilities panel, click on OpenChoice Talker Listener and click Start …
Faq Id69181
I have connected my MSO2000 (or DPO2000) series oscilloscope to a PictBridge printer using a USB-B to USB-B cable. But nothing is printing on the printer when I press the print button. What is wrong?
You should be using a USB-B to USB-A cable.  Connect the USB-B end of the cable to the instrument rear panel USB device port (marked with PictBridge symbol), and connect the USB-A end of the cable to the USB host port (marked with PictBridge symbol) …
Faq Id59556
Which probes are compatible with oscilloscopes with the TekVPI probe interface?
There are a couple different types of TekVPI interfaces, one with a notch and one without. The notch was implemented later and was put in place because the front end was designed differently and communicates uniquely with those types of probes …
Faq Id56226
How to decode the RS422 or RS485 bus on the DPO2000/MSO2000+ DPO3000/MSO3000 or the DPO4000/MSO4000?
1) It requires the application module DPOXCOMP.  X refers to the different model.  For example, DPO2000 requires the DPO2COMP.2) It uses the RS232 bus decode, however, the polarity need to be modified to “Inverted”There are two other types of …
Faq Id59511
Where can I find an IVI driver for TDS200+ TDS1000/TDS2000+ TDS1000B/TDS2000B+ TDS2000C+ TPS2000+ TDS3000/TDS3000B/TDS3000C+ DPO2000/MSO2000+ DPO3000/MSO3000+ DPO4000/MSO4000 series?
IVI drivers to support LabView, LabWindows/CVI, and LabView SignalExpress can be found on the National Instruments Developer Zone, http://zone.ni.com/.For MSO3000 series please use the drivers posted for the DPO3000 series.For MSO4000 series please …
Faq Id60176
What are the key differences between the TBS2000, MSO/DPO2000B, TBS1000B, and TDS2000C oscilloscopes?
Below is a condensed table of key specifications of this range of oscilloscopes. More information can be found on the data sheets or in the manuals of each of the oscilloscope product lines. Note that there are feature options available to each …
Faq Id72201
We have a classroom where we need to project the screen of an oscilloscope. Being a school+ what is the lowest cost solution for connecting a projector to a scope?
The lowest cost solution is to use the DPO2012 with the DPO2CONN module. It provides a VGA output of the screen, as well as the Ethernet port for PC connectivity.
Faq Id63991
Can the P6316, P6516, or P6616 logic probes be used interchangeably?
The simple answer is no they can't be used interchangeably. The front end of the logic channels are different so different logic probes are needed between the scopes.   For MSO2000/B, MSO3000, and MDO3000 Series oscilloscopes, only the P6316 logic …
Faq Id59166
Can I convert my wfm files to an open format+ such as a CSV (comma separated values) file?
You can use one of the following three WFM to ASCII converters. Converter for TDSxxx - works with files created by TDSx00 series (for example, TDS500 series) Converter for TDS5xxx,TDS6xxx, TDS7xxx, DPO7xxx,DPO70xxx, DSA70xxx Converter for the …
Faq Id56386
Can active probes with TekProbe interface (such as a P6205) be used on the DPO4000B or MSO4000B series scopes?
Yes. A TPA-BNC adaptor is required for people to connect legacy TekProbe interface probes to the new TekVPI interface. The adapter works on any TekVPI scopes inlcuding the MSO/DPO/MDO4000/B/C, MSO/DPO/MDO3000 MSO/DPO2000/B or MSO/DPO5000/B or …
Faq Id60416
Programing - How to get and plot a waveform from DPO/MSO/MDO4000 Series scope in Python
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …
Faq Id64796
I cannot see my signal on the Oscilloscope. What can I do?
You have many options to help diagnose this issue, below are a few suggestions to get started. If you find yourself needing more help, please connect with our Technical Support Center. You can get started by pressing the "Contact Us" button on the …
Faq Id63686
What operating system does the TDS1000B+ TDS2000B+ TPS2000+ MSO/DPO2000+ TDS3000C+ MSO/DPO3000 and MSO/DPO4000 use? And are they susceptible to viruses?
The above oscilloscopes use closed embedded real-time operating systems and do not have the capability to create, modify, run or save programs that are on a USB device or LAN .  Therefore, they are not susceptible to virus attacks and cannot spread …
Faq Id56996
Is the .ISF waveform file format file used on the DPO2000/MSO2000+ DPO3000/MSO3000+ DPO4000/MSO4000 series compatible with the Arb Express software?
The DPO2000/MSO2000, DPO3000/MSO3000, DPO/MSO4000 series format files cannot be imported into Arb Express.
Faq Id63786
What probe interface does my oscilloscope have?
Oscilloscope series Probe interface CSA7000/CSA7000B TekConnect DPO2000 TekVPI DPO3000 …
Faq Id64251
Do you have a detailed application note on how to use DPO/MSO2000 Series Oscilloscopes for debugging embedded systems+ serial signals+ power designs+ and general purpose design applications?
Please see the MSO2000 / DPO2000 Series Lab Exercise Book for more details.
Faq Id59261
How do I Set up a Military Standard 1553 serial bus decode?
For doing Military Standard 1553 bus decode Tektronix recommends using a DPO/MSO/MDO 2000 or higher series oscilloscope. This feature can be purchased as a module or option key on any of these types of oscilloscopes. Start by turning it on the bus …
Faq Id64776
How can I increase the measurement accuracy using automated measurements vs cursors?
While Cursors are quick and easy at approximating measurements, using the automated measurements can give you a much better and accurate measurement results. Here are some techniques to be successful in making accurate measurements. Always use …
Faq Id62606
What is the format of the .isf file?
The ISF format is the same as what the scope would send in response to the WAVFrm? command via an external program.The response to the WAVFrm? command is documented in the programmers manual for your instrument, which you can download from the …
Faq Id54941
How do I utilize the XY display feature on a DPO/MSO/MDO4000 Series oscilloscope?
The XY display format can be used to measure the phase relationship between two or more synchronous signals. This measurement technique involves inputting one signal into the vertical system as usual and then another signal into the horizontal system …
Faq Id64666
Where Do I Download USB Device Driver For Tektronix USB Instruments?
Tektronix USB instruments use and require a generic USB Device Driver, referred to as a USB Test & Measurement Class driver or USBTMC driver. USBTMC is a subclass of the USB specification.  This driver is typically included with the Virtual …
Faq Id60216
Where can I find the manual for the application module for my MSO2000+ DPO2000+ MSO3000+ DPO3000+ MSO4000+ or DPO4000 series oscilloscope?
The application modules are all addressed in the user manual for your oscilloscope. Only the power analysis module (DPO3PWR and DPO4PWR) has its own user manual.You could also refer to the Lab Exercise Book for different series oscilloscope in the …
Faq Id60191
What is the format of the .isf file?
The ISF format is the same as what the scope would send in response to the WAVFrm? command via an external program.The response to the WAVFrm? command is documented in the programmers manual for your instrument, which you can download from the …
Faq Id53511
I am experiencing front panel operational issues with my MSO/DPO2000 and MSO/DPO3000.  At times the front panel controls are inoperative or my cursors do not move normally or scaling does not work. 
This could be related to the instrument software currently installed on your instrument.  Check to see what software version is currently installed on your instrument. For a MSO/DPO3000, should have software V2.16 or greater For a MSO/DPO2000, should …
Faq Id64581
How do I utilize the math channel feature on a DPO/MSO/MDO3000 or DPO/MSO/MDO4000 Series oscilloscope?
There are three main functionalities on the Math button on this scope. They range from Dual Waveform Math, FFT (Fast Fourier Transform), and Advance Math. These three functionalities have a range of abilities and are explained in this short YouTube …
Faq Id64656
FIRMWARE TO SUPPORT MSODPO2000B OSCILLOSCOPES, V1.56
This firmware is an upgrade for all DPO2000B and MSO2000B Series oscilloscopes.

Part Number: 063447301
Firmware
Mixed Signal Oscilloscopes
Offering up to 200 MHz bandwidth and 1 GS/s sample rate, the MSO/DPO2000B Mixed Signal Oscilloscope Series from Tektronix delivers advanced debug features at an entry-level price. Quickly find and diagnose problems in complex designs with up to 20 …

Literature Number: 3GW-28413-8
Datasheet
Active FET Probes

Literature Number: 51W-23069-0
Datasheet
MSO2000/B and DPO2000/B Series
Oscilloscopes Declassification and Security

This document includes information that is necessary to clear or sanitize the product so it can be removed from a secured area, such as when returning the product for repair.


Part Number: 077010801
Declassification
MSO2000B and DPO2000B Series
Oscilloscopes User Manual

This MSO2000B and DPO2000B series Installation and Safety Manual explains basic safety and installation procedures.
Part Number: 071307801
User
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series
Oscilloscopes Programmer Manual

This manual explains the use of commands for remotely controlling your oscilloscope.
Part Number: 077073800
Programmer
DPO2CONN
Connectivity Module for MSO/DPO2000B and MSO/DPO2000 Series Oscilloscopes Installation Manual

This document contains information that is necessary to install a product software and/or hardware kit. The instructions may include configuration, adjustment, functional check, and operating instructions related to the kit installation.
Part Number: 071234601
Field Install Instructions
MSO/DPO2000B and MSO/DPO2000 Series
Oscilloscopes Application Module Installation Manual

This document contains information that is necessary to install a product software and/or hardware kit. The instructions may include configuration, adjustment, functional check, and operating instructions related to the kit installation.
Part Number: 071233001
Field Install Instructions
MSO2000B and DPO2000B Series
Oscilloscopes Specifications and Performance Verification Technical Reference

This document provides complete product specifications and may also explain how to verify that the product is performing according to the specifications
Part Number: 077073500
Performance Verification
MSO2000B and DPO2000B Series
Oscilloscopes User Manual

This MSO2000B and DPO2000B series user manual explains how to operate the oscilloscope and includes installation procedures. It also provides information about features, functions, and applications.
Part Number: 077072400
Primary User
DPO2000 and MSO2000 Series
Oscilloscopes User Manual

This MSO2000 and DPO2000 series user manual explains how to operate the oscilloscope and includes installation procedures. It also provides information about features, functions, and applications.
Part Number: 071231902
Primary User
Educator's Resource Kit
Resource Kit for Educator's Instructions

This introduction to the Educator's Resource Kit lists the kit contents, how to locate signals on the training board, and compliance information for the training board.
Part Number: 071269200
User
DPO2000 and MSO2000 Series Rev A
Oscilloscopes Programmer Manual

This manual explains the use of commands for remotely controlling your oscilloscope.
Part Number: 077009701
Programmer
MSO/DPO2000, MSO/DPO3000, and MSO/DPO4000 Series
Oscilloscope Demo 2 Board Instruction Manual

This MSO2000, DPO2000, MSO3000, DPO3000, MSO4000 and DPO4000 Series Oscilloscope Demo 2 Board Instruction Manual provides examples to help you learn how to use the oscilloscope.
Part Number: 071234701
User
DPO2000 and MSO2000 Series
Oscilloscopes Service Manual

This Service manual provides adjustment, troubleshooting, and repair information, to repair the oscilloscope to the module level
Part Number: 071233100
Service
DPO2000 and MSO2000 Series
Oscilloscopes Specifications and Performance Verification Technical Reference

This document provides complete product specifications and may also explain how to verify that the product is performing according to the specifications
Part Number: 077009600
Performance Verification
DPO2000 and MSO2000 Series
Application Module Installation Manual

This document contains information that is necessary to install a product software and/or hardware kit. The instructions may include configuration, adjustment, functional check, and operating instructions related to the kit installation.
Part Number: 071233000
Field Install Instructions
DPO2000 and MSO2000 Series
Oscilloscope Declassification and Security Instructions

This document includes information that is necessary to clear or sanitize the product so it can be removed from a secured area, such as when returning the product for repair.
Part Number: 077010800
Declassification
DPO2CONN Installation Manual
Connectivity Module for DPO/MSO2000 Series Oscilloscopes Installation Manual

This document contains information that is necessary to install a product software and/or hardware kit. The instructions may include configuration, adjustment, functional check, and operating instructions related to the kit installation.
Part Number: 071234600
Field Install Instructions
RMD2000
DPO2000 and MSO2000 Rackmount Kit

This document contains information that is necessary to install a product software and/or hardware kit. The instructions may include configuration, adjustment, functional check, and operating instructions related to the kit installation.


Part Number: 071233200
Field Install Instructions
1101A, 1102, 1103
Power Supplies Instruction Manual

This document contains information that supports basic instrument operation as well as how to service to the module level.
Part Number: 070827602
Primary User
TEKVISA Connectivity Software - V4.2.0
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …

Part Number: 066093812
Driver
DPO2000, MSO2000, DPO3000 and DPO4000, MSO3000 and MSO4000, MDO3000 and MDO4000 and MDO3 IVI Driver - V1.5
The Tektronix MSO/DPO2000, MDO/MSO/DPO3000, MDO/MSO/DPO4000 and MDO3 IVI Driver is an IVI class-compliant driver. It complies with Scope Class specifications (IVI-4.1) as defined by the IVI foundation. An IVI class-compliant specific driver for an …

Part Number: 066133104
Driver
TEKVISA CONNECTIVITY SOFTWARE - V4.1.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …

Part Number: 066093811
Driver
Tektronix Openchoice Desktop Application TDSPCS1 - v2.6
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …

Part Number: 066093914
Utility
Probing Techniques for Accurate Voltage Measurements on Power Supplies with Oscilloscopes
Making oscilloscope voltage measurements on power supplies is fundamental, but not without challenges. Much is  written on oscilloscopes, but probing techniques are often taken for granted. This application note focuses on probing and …

Literature Number: 51W-60161-3
Application Note
XYZs of Oscilloscopes Primer
After reading this primer, you will be able to: Describe how oscilloscopes work Describe the differences between analog, digital storage, digital phosphor, and digital sampling oscilloscopes Describe electrical waveform types Understand basic …

Literature Number: 03Z-8605-7
Primer
Wave Inspector® Navigation and Search: Simplifying Waveform Analysis
Modern digital oscilloscopes can capture massive amounts of data which must then be analyzed. Discover how the Tektronix Wave Inspector® navigation and search capability gives you the tools to extract the answers you need fast and efficiently.

Literature Number: 48T-19039-9
Application Note
RC4 Wireless Lights It Up with Tektronix MSO2000 Series
James Smith at RC4 develops custom wireless dimming and control products, for high-profile clients like Cirque du Soleil and Disney. Find out how James used the MSO2024 to shave hours off troubleshooting, and what impressed James so much that he …

Literature Number: 3GW-24465-0
Case Study
Troubleshooting Three Phase Permanent Magnet AC Motor Using Tektronix MSO2024 Oscilloscope
This paper describes troubleshooting motor controls in a solar-powered vehicle using an MSO2000 Series Mixed Signal Oscilloscope.  Written by members of the Oregon State University Solar Vehicle Team, winners of the Formula Sun Grand Prix.

Literature Number: 3GW-30483-0
Whitepaper
10 Factors in Choosing a Basic Oscilloscope.
This guide will give you a quick overview of the key factors that determine the suitability of a basic oscilloscope for the job at hand. Learn the XYZ's of Oscilloscopes »  

Literature Number: 3GW_60848_1
Brochure
Power Supply Measurement and Analysis Primer
A power supply is a component, subsystem, or system that converts electrical power from one form to another; commonly from alternating current (AC) utility power to direct current (DC) power. The proper operation of electronic devices ranging from …

Literature Number: 55T-18412-6
Primer
Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope
Problems with setup and hold timing are among the most challenging to identify.  Mixed signal oscilloscopes (MSOs) are able to capture both analog and digital representations of signals, making them well-suited for identifying digital timing problems …

Literature Number: 55W-61095-0
Application Note
Oscilloscope Fundamentals: Capturing Your Signal in 3 Easy Steps Poster
This 11"x17" printable poster gives the basic steps for getting a stable waveform on an oscilloscope: setting the vertical scale, setting the horizontal scale, and setting the trigger.  It also includes critical steps for making connections (probing) …

Literature Number: 3GW-60028-0
Poster
Oscilloscope Selection Guide
From basic signal-checking to high-performance analysis, this selection guide gives an overview of the complete range of oscilloscopes from Tektronix. Comparison tables give high-level specifications and features, and indicate the major differences …

Literature Number: 46W-31080-7
Selection Guide
MSO/DPO2000B Series vs Rigol MSO/DS2000 Series
A comparison of the Tektronix MSO/DPO2000B Series Oscilloscopes versus the Rigol MSO/DS2000 Series Oscilloscopes.

Literature Number: 3GW-28435-2
Competitive
MSO/DPO2000B Series vs. Agilent DSO1000A Series
A comparison of the Tektronix MSO/DPO2000 Series Oscilloscopes versus the Agilent DSO1000A Series Oscilloscopes.

Literature Number: 3GT-24447-0
Competitive
MSO/DPO2000B Series vs. Agilent/Keysight X2000 Series
When comparing oscilloscopes, don’t forget to look at the “true” value in your scope. Tektronix bench oscilloscopes are packed with innovative features to help you get your job done faster, built right into the scope. And, with a comprehensive set of …

Literature Number: 48W-30248-0
Competitive
MSO/DPO2000B Series vs. R&S HMO1002 Series
Review the comparison of the MSO/DPO2000B Series and the R&S HMO1002 Series.

Literature Number: 3GW-30640-1
Competitive
MSO/DPO2000B Series vs Rigol DS1000C
A comparison of the Tektronix MSO/DPO2000B Series Oscilloscopes versus the Rigol DSO1000C Series Oscilloscopes.

Literature Number: 3GW-22824-1
Competitive
MSO/DPO2000B Series vs. Agilent MSO/DSO2000 X-Series Fact Sheet
Side-by-side comparison on important features like serial triggering and decode, waveform navigation and search, waveform capture rate, embedded system debugging, and more.

Literature Number: 3GT-26814-0
Competitive
Making Accurate Current Measurements on Power Supplies with Oscilloscopes
Accurately measuring current with oscilloscopes is essential for power supply design and general electronics. Learn how to measure current using shunt resistors and voltage probes, and how to use clamp-on current probes with your oscilloscope. Get …

Literature Number: 51W-60171-2
Application Note
Making MicroVolt Biomedical Measurements
Learn how paying attention to grounding, isolation, and probe shielding can produce very refined biomedical measurement, inexpensively.

Literature Number: 48W-28061-0
Technical Brief
Smiths Detection Relies on Tektronix to Take the Trouble out of Troubleshooting
A team of engineers at Smith Detection needed to quickly, efficiently and accurately identify and resolve problems during the development of complex handheld devices. Learn how Smith Detection engineers used Tektronix bench instruments to identify a …

Literature Number: 48W-24397-0
Technical Brief
Dealing with a Noisy Signal: Oscilloscope Tools to Simplify Your Measurements
Noise is a common and pervasive problem in electrical circuits.  Learn more about the available features on your oscilloscope to help you deal with noise, including the innovative FilterVu™ Variable Low Pass Filter only available on the Tektronix …

Literature Number: 3GK-22049-0
Application Note
Tektronix Probe Selection Guide
Tektronix probes ensure the highest signal fidelity possible from your device-under-test to your oscilloscope. With over 100 probe choices available, all perfectly matched to our industry-leading oscilloscopes, you can find the probe you need for …

Literature Number: 60W_14232_10
Product Selector Guide
Tektronix MSO/DPO2000B Series vs. Rigol DS1000B Series
A comparison of the Tektronix MSO/DPO2000B Series Oscilloscopes versus the Rigol DS1000B Series Oscilloscopes.

Literature Number: 3GT-28434-0
Competitive
TekVPI Probe Power Requirements on Digital Phosphor Oscilloscopes
This technical brief gives configuration information for using TekVPI probes with oscilloscopes that include the TekVPI probe interface. It gives the maximum internal probe power available from each oscilloscope series, and lists the power …

Literature Number: 55W-28827-7
Technical Brief
Measurement Data Logging with TekBench Oscilloscope Control Software
This application note describes how to use TekBench™ Software and a Tektronix oscilloscope to perform measurement data logging for evaluating a design’s reliability in a room temperature environment, such as a project laboratory.

Literature Number: 61W-61442-0
Application Note
Serial Support Using Tektronix Oscilloscopes and Optional Software
Tektronix oscilloscopes offer a portfolio of optional analysis capabilities to simplify serial bus debug or compliance verification. This selection matrix shows which serial standards are supported by each of the oscilloscope series.  

Literature Number: 55W-29028-13
Selection Guide
New Tektronix Entry-Level Oscilloscope Series Puts Embedded System Debug within Easy Reach
Attractively Priced MSO/DPO2000B Series Oscilloscopes Feature New 70MHz Models, Full Serial Bus Decode, Advanced TriggeringBEAVERTON, Ore., October. 16, 2012 - Tektronix, Inc., the world's leading manufacturer of oscilloscopes, today introduced the …
News Release
Tektronix Toolbars for Microsoft Office, V4.0.4
Tektronix Toolbars for Microsoft Office v4.0.4 provide toolbars (add-ins) for Microsoft Excel and Microsoft Word.This version of Toolbars requires OpenChoice TekVISA v4.0.0 or higher be preinstalled on the PC or Windows based Oscilloscope.The Toolbar …

Part Number: 066133202
Utility
DPO2000 MSO2000 Maintenance Release, Version 1.56
This firmware is an upgrade for all DPO2000 and MSO2000 Series oscilloscopes.

Part Number: 063414309
Firmware
TEKVISA CONNECTIVITY SOFTWARE, V4.0.4
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol. When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …

Part Number: 066093809
Driver
PILOT FIRMWARE TO SUPPORT MSODPO2000B OSCILLOSCOPES, V1.52
Firmware supports 70MHz 2 and 4 channel scopes in addition to 2 channel 200 MHz scopes.

Part Number: 063447300
Firmware
DPO2000, DPO3000, DPO4000 IVI Driver
The Tektronix DPO2000, DPO3000, DPO4000 IVI Driver is an IVI class-compliant driver. It complies with Scope Class specifications (IVI-4.1) as defined by the IVI foundation. An IVI class-compliant specific driver for an oscilloscope exports the API …

Part Number: 066133101
Driver
DPO2000 MSO2000 Maintenance Release, Version 1.52
This firmware is an upgrade for all DPO2000 and MSO2000 Series oscilloscopes.

Part Number: 063414308
Firmware
DPO2000 MSO2000 Maintenance Release V1.39
This firmware is an upgrade for all DPO2000 and MSO2000 Series oscilloscopes.

Part Number: 063414307
Firmware
DPO2000 MSO2000 Maintenance Release V1.35
This firmware is an upgrade for all DPO2000 and MSO2000 Series oscilloscopes.

Part Number: 063414306
Firmware
DPO2000 MSO2000 Maintenance Release V1.29
DPO2000/MSO2000 V1.29 update to replace V1.25 or earlier. This firmware image contains a change to the front panel microprocessor code to improve front panel knob operation, making it smoother and more linear.

Part Number: 063414304
Firmware
NI SIGNALEXPRESS TEKTRONIX EDITION v2.5.1
National Instruments SignalExpress(tm) Tektronix Edition provides the industry's first true USB plug-n-play connectivity for instrumentation offering an intuitive drag-and-drop user interface that does not require any programming. SignalExpress(tm) …

Part Number: 066077003
Application