Keithley 2700 Multimeter/Data Acquisition/Switch Systems

Each Series 2700 system combines precision measurement, switching, and control in a tightly integrated enclosure for either rack-mount or bench-top applications. Although the core functionality and programming of all three systems are identical, each mainframe has unique capabilities. For example, the Model 2701 provides a 10/100BaseTX Ethernet interface, and the Model 2750 offers extended low ohms measurement capability. All models are compatible with the same line of plug-in multiplexer, matrix, or control modules. See all digital multimeters »

See Keithley’s new DAQ6510 6½-Digit Data Acquisition and Logging Multimeter System.

keithley-logo

Base Price
US $2,110 - US $3,200
Buy/Quote Questions? Chat Now

Features

Benefits

Choice of two-slot (2700, 2701) or five-slot (2750) mainframes Makes it easy to create an automated test system with up to 80 channels/96 crosspoints or 200 channels/240 crosspoints.
Built-in algorithms for a variety of thermocouples, RTDs, and thermistors. Makes temperature measurements as easy as hooking up a sensor because the system does the rest.
12 switch and control modules from which to choose Simplifies selecting just the right module to meet your application needs
Open lead detection Protects against false readings due to lead disconnections.
Battery-backed non-volatile memory Protects valuable data and allows resuming scans where they stopped after a power failure.
Channel Monitor function Allows viewing a channel of interest without interrupting a scan
Selectable power line cycle integration Provides rejection of noise from line cycle interference, the most common source of noisy readings.
Model Maximum Switching Channels Other Features Connectivity Mainframe Size No. of Card Slots Description List Price
2701 up to 80 Integrated DMM LAN / RS232 1/2 rack, 2U 2 Configure & Quote
2700 up to 80 Integrated DMM GPIB / RS232 1/2 rack, 2U 2 US $2,110
Configure & Quote
2700/7700 up to 80 Integrated DMM. Includes model 7700, 20-channel differential multiplexer module GPIB / RS232 1/2 rack, 2U 2 US $2,650
Configure & Quote
2750 up to 200 Integrated DMM GPIB / RS232 Full rack, 2U 5 US $3,200
Configure & Quote
Model Maximum Switching Channels Other Features Connectivity Mainframe Size No. of Card Slots Description List Price
2701 up to 80 Integrated DMM LAN / RS232 1/2 rack, 2U 2 Configure & Quote
2700 up to 80 Integrated DMM GPIB / RS232 1/2 rack, 2U 2 US $2,110
Configure & Quote
2700/7700 up to 80 Integrated DMM. Includes model 7700, 20-channel differential multiplexer module GPIB / RS232 1/2 rack, 2U 2 US $2,650
Configure & Quote
2750 up to 200 Integrated DMM GPIB / RS232 Full rack, 2U 5 US $3,200
Configure & Quote
Datasheet 2000-BENCHKIT
Datasheet Accessory
MULTI MODEL BENCH CONVERSION KIT
Datasheet 4288-1
Datasheet Accessory
Description Datasheet SINGLE FIXED RACK MOUNTING KIT
Datasheet 4288-2
Datasheet Accessory
DUAL FIXED RACK MOUNTING KIT
Datasheet 4288-5
Datasheet Accessory
RACK KIT
Datasheet 4288-7
Datasheet Accessory
FIXED REAR RACK MOUNT KIT
Datasheet 7007-1
Datasheet Accessory
SHIELDED GPIB CABLE,1M (3.2FT)
Datasheet 7007-2
Datasheet Accessory
SHIELDED GPIB CABLE,2M (6.5FT)
Datasheet 7007-3
Datasheet Accessory
SHIELDED GPIB CABLE,3M (10FT)
Datasheet 7007-4
Datasheet Accessory
SHIELDED GPIB CABLE, 4M 13 FT
Datasheet 7009-5
Datasheet Accessory
5 FT. SHIELDED RS-232 CABLE
Datasheet 7010
Datasheet Accessory
IEEE ADAPTER
Datasheet 8620
Datasheet Accessory
SHORTING PLUG
Datasheet Datasheet Accessory
Description Datasheet 2000-BENCHKIT MULTI MODEL BENCH CONVERSION KIT
4288-1 SINGLE FIXED RACK MOUNTING KIT
Description Datasheet 4288-2 DUAL FIXED RACK MOUNTING KIT
Description Datasheet 4288-5 RACK KIT
Description Datasheet 4288-7 FIXED REAR RACK MOUNT KIT
Description Datasheet 7007-1 SHIELDED GPIB CABLE,1M (3.2FT)
Description Datasheet 7007-2 SHIELDED GPIB CABLE,2M (6.5FT)
Description Datasheet 7007-3 SHIELDED GPIB CABLE,3M (10FT)
Description Datasheet 7007-4 SHIELDED GPIB CABLE, 4M 13 FT
Description Datasheet 7009-5 5 FT. SHIELDED RS-232 CABLE
Description Datasheet 7010 IEEE ADAPTER
Description Datasheet 8620 SHORTING PLUG
View Datasheet Data Sheet Module Description
View Datasheet 7700 20 CHANNEL MULTIPLEXER Description
View Datasheet 7702 40 CHANNEL DIFFERENTIAL MULTIPLEXER Description
View Datasheet 7705 40 CHANNEL CONTROL MODULE Description
View Datasheet 7706 ALL IN ONE I/O MODULE Description
View Datasheet 7708 40 CHANNEL DIFFERENTIAL MULTIPLEXER MODULE Description
View Datasheet 7707 MULTIPLEXER DIGITAL I/O MODULE Description
View Datasheet 7709 6 X 8 MATRIX MODULE Description
View Datasheet 7703 32 CHANNEL HI SPEED DIFFERENTIAL MULTIPLEXER Description
View Datasheet 7701 32 CHANNEL DIFFERENTIAL MULTIPLEXER Description
View Datasheet 7710 20 CHANNEL 60V SOLID STATE MULTIPLEXER CARD Description
There’s much more to choosing a DMM than just its number of digits. With Tektronix wide range of DMMs, you can count on advanced features, speed, high basic accuracy, integration flexibility, and …
1m 28s
KickStart Instrument Control Software Datasheet
KickStart Software simplifies what you need to know about your instrument so that in just minutes you can take the instrument out of the box and get real data on your device.  KickStart Software enables quick test setup and data visualization when …

Literature Number: 1KW-60965-4
Datasheet

Faq Id72021
My Model 2701 is not automatically discovered in the KickStart instrument pane.  How do I connect to the Model 2701?
The Model 2701 is not an LXI-C instrument.  You must manually add its IP address in KickStart.  Click on the “Advanced” section of the Instrument Pane in KickStart version 2.0.0.  Enter the IP address for the Model 2701.
Faq Id470101

Faq Id70151
What are the current shunt resistors in the current measurement function for the 2700 Series DMM?  
There are two shunt resistors. One is  5.1 ohms for the 20mA range and the other is 0.1 ohms for the 100mA, 1A, and 3A ranges.
Faq Id468841

Faq Id71301

Faq Id69751

Faq Id70166

Faq Id71281

Faq Id72016

Faq Id71296

Faq Id69551

Faq Id71681

Faq Id71661

Faq Id71291

Faq Id71311

Faq Id71306

Faq Id70146

Faq Id69811

Faq Id69691

Faq Id69646
 Are there any example programs for the IVI driver?
When the IVI driver for your measurement instrument is installed, several example programs are also installed.If LabVIEW is already installed on the target system when the IVI driver is installed, then a subfolder, KE2700 or KE6485, in the National …
Faq Id72161

Faq Id69651

Faq Id71961

Faq Id70116

Faq Id69681

Faq Id69706

Faq Id71321

Faq Id69656

Faq Id69711

Faq Id69686

Faq Id71711

Faq Id70156

Faq Id69671

Faq Id71486

Faq Id71286

Faq Id71326

Faq Id71481
7708 40-Channel Differential Multiplexer Module
Datasheet
7710 20-Channel Solid State Differential Multiplexer w/Automatic CJC
Datasheet
KickStart Quick Start Guide

KickStart Instrument Control Software lets you start making measurements in minutes without complex instrument programming. KickStart allows you to do I-V characterization, data acquisition and logging, and power supply control on a variety of Keithley products.


Part Number: KKS-903-01H
Primary User
Model 2701 Ethernet-Based DMM / Data Acquisition System Service Manual

Model 2701 Ethernet-Based DMM / Data Acquisition System Service Manual Rev. A 1-27-03 Changed to Publish to Web-Yes
Part Number: 2701-902-01
Service
Keithley Instruments Safety Precautions
Safety Precautions PA

This document contains safety information for Keithley Instruments products.


Part Number: 071341102
User
Model 4299-7 Fixed Rack-Mount Kit Assembly and Mounting Instructions
This document contains the parts list and installation information for products that can be mounted with this rack-mount kit.

Model 4299-7 Fixed Rack Mounting Kit Assembly and Mounting Instructions
Part Number: PA-1065E
User
Using the Model DAQ6510 in a Model 2700 or 2701 application
Using the Model DAQ6510 in a Model 2700 or 2701 application

This document provides information about using the DAQ6510 as a drop-in replacement in an existing Keithley Instruments Model 2700 or 2701 test system application.


Part Number: 077146500
User
KickStart 2.0 Quick Start Guide Beta
KickStart 2.0 Quick Start Guide Beta

This guide contains basic instructions for the KickStart software.


Part Number: KKS-903-01E
User
KickStart 1.9 Quick Start Guide
KickStart 1.9 Quick Start Guide

This guide contains basic instructions for the KickStart software. This version is for users that did not upgrade to KickStart 2.0 and still use KickStart 1.9.8.


Part Number: KKS-903-01
Primary User
Model 2701 Ethernet-Based DMM / Data Acquisition User’s Manual

Model 2701 is a 6½-digit high-performance multimeter/data acquisition system. It can measure voltage (DC and AC), current (DC and AC), resistance (2- and 4-wire), temperature (thermocouple, thermistor, and 4-wire RTD), frequency and period, and test continuity.
Part Number: 2701-900-01G
User
Model 2700 Multimeter/Switch System User’s

Model 2700 is a 6½-digit high-performance multimeter/data acquisition system. It can measure voltage (DC and AC), current (DC and AC), resistance (2- and 4-wire), temperature (thermocouple, thermistor, and 4-wire RTD), frequency and period, and test continuity.


Part Number: 2700-900-01K
Primary User
Model 2701 Ethernet-Based DMM / Data Acquisition System Instrument Networking Instruction Manual
Model 2701 Ethernet-Based DMM / Data Acquisition System Instrument Networking Instruction Manual Instruction Manual

Keithley's Model 2701 is the industry's first multipoint measurement and control system that fully integrates instrument quality resolution and sensitivity with Ethernet long distance networking capability. This allows for sensitive measurements in a distributed data acquisition environment using long distance industry standard communications


Part Number: 2701-904-01D
User
Model 2700S Integra Series Quick Start Guide

This Quick Start Guide is intended to get a new user familiar with the operation of the 2700S Integra Series instruments. It summarizes operation for all basic measurement functions and most features of the Integra instruments. It also summarizes the operation of the Model 7700 switching module, which adds switching and scanning capabilities to an Integra measurement system.
Part Number: 2700S-903-01B
User
Model 7706 Multiplexer Card User's Manual for use with the 2700, 2701, or 2750
User's Manual for 7706 All-in-One Multiplexer Card User's Manual User Manual

The User's Manual for the 7706 All-in-One I/O module describes how to set up and use the 7706.
Part Number: PA-719E
Primary User
Model 2700 ROM Upgrade Notice for Model 7707 and 7709 Support

Model 2700 ROM Upgrade Notice for Model 7707 and 7709 Support
Part Number: PA-774B
User
Model 27xx (Models 2700, 2701, and 2750) Japanese User's Quick Reference Manual

Model 27xx (Models 2700, 2701, and 2750) Japanese User's Quick Reference Manual
Part Number: 27XXJ-903-01A
User
Model 7705 Control Module Connection and Wiring Information User's Guide for use with 2700, 2701, and 2750
User's Guide for the 7705 40-Channel Control Module User Manual

7705 40-Channel Control Module Connection and Wiring Information
Part Number: PA-696D
Primary User
Model 7708 40-Channel Differential Multiplexer with Automatic CJC User's Guide for use with the 2700, 2701, or 2750
User's Guide for the 40-Channel Differential Multiplexer Module

The 7708 40-Channel Differential Multiplexer with Automatic CJC User's Guide describes how to set up and use the 7708.


Part Number: PA-744C
User
Model 7709 6x8 Matrix Module User's Guide for use with the 2700, 2701, or 2750
The 7709 6x8 Matrix Module User's Guide describes how to set up and use the 7709 module User Manual

The 7709 2-Pole, 6 X 8 Matrix Module User's Guide describes how to set up and use the 7709 module.


Part Number: PA-771B
User
Models 7711 and 7712 Single-Pole Dual 1x4 RF Multiplexer Module instructions for use with the 2700, 2701, and 2750
User's Guide for the 7711 2 GHz 50 ohm RF module and 7712 3.5 GHz 50 ohm RF module

The Models 7711 and 7712 Single-Pole Dual 1x4 RF Multiplexer Modules User's Guide describes how to set up and use the modules for use with the Integra product line, including the 2700, 2701, and 2750.


Part Number: PA-818B
Primary User
Model 7700, 7702 and 7703 Multiplexer Modules Connection and Wiring Information for use with the 2700, 2701, and 2750
User Manual

Model 7700, 7702 and 7703 Multiplexer Modules Connection and Wiring Information
Part Number: PA-695D
Primary User
Model 2700 ROM Upgrade Notice for Model 7708 Support Read This First

Model 2700 ROM Upgrade Notice for Model 7708 Support Read This First
Part Number: PA-763B
User
Model 7701 Differential Multiplexer Module User's Guide for Models 2700, 2701, and 2750
User's Guide for the 7701 Low-Voltage 32-Channel Differential Multiplexer User Manual

User's Guide for the 7701 Low-Voltage 32-Channel Differential Multiplexer Module
Part Number: PA-769B
Primary User
Model 2750 Multimeter/Switch System User's Manual

Model 2750 Multimeter/Switch System User's Manual
Part Number: 2750-900-01F
Primary User
Model 2700/2750 ROM Upgrade Notice for Models 7701, 7711, and 7712
User Manual

Model 2700/2750 ROM Upgrade Notice for Models 7701, 7711, and 7712
Part Number: PA-828B
User
Model 7707 Differential Multiplexer Card User's Guide for use with the 2700, 2701, or 2750
User' Guide for the 7707 10-channel differential multiplexer card User Manual

7707 Differential Multiplexer Card User's Guide provides installation and operation instructions.


Part Number: PA-770B
User
Model 2700 Multimeter/Switch System Japanese User's Manual

Model 2700 Multimeter/Switch System Japanese User's Manual
Part Number: 2700J-900-01A
User
Model 7710 Multiplexer Card User's Guide for use with the 2700, 2701, or 2750
User's Guide for the 7710 20-Channel Solid State/Long-Life Differential Multiplexer with Automatic CJC User Manual

User's Guide for the 7710 20-Channel Solid-State Differential Multiplexer with Automatic CJC


Part Number: PA-847B
User
Model 2700 Multimeter/Data Acquisition System Service Manual Rev C
User Manual

The Model 2700 Multimeter/Data Acquisition System Service Manual, Rev. C, provides performance verification, calibration, maintenance, and troubleshooting information.
Part Number: 2700-902-01C
User
Model 2750 Multimeter/Switch System Service Manual Rev. B
User Manual

Model 2750 Multimeter/Switch System Service Manual Rev. B
Part Number: 2750-902-01B
User
Model 2700 Xlinx 2.1 Software Read This First

Model 2700 Xlinx 2.1 Software Read This First
Part Number: PA-762A
User
KickStart Instrument Control Software Version 2.2.1 (Windows 10, 8, 7 compatible)
KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the ability to …

Part Number: KICKSTART-2.2.1
Application
KickStart Instrument Control Software Version 2.2.0 (Windows 10, 8, 7 compatible)
"KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the …

Part Number: KICKSTART-2.2.0
Application
KickStart Instrument Control Software Version 2.1.1 (Windows 10, 8, 7 compatible)
"KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the …

Part Number: KICKSTART-2.1.1
Application
KickStart Instrument Control Software Version 2.1.0 (Windows 10, 8, 7 compatible)
"KickStart Software for the PC enables quick test setup and data visualization when using one or more instruments. Key Features • Save time by automating data collection of millions of readings. • Set up a multi-instrument test with the …

Part Number: KICKSTART-2.1.0
Application
Keithley I/O Layer version C10 (Windows 10, 8, 7 Compatible)
Keithley I/O Layer version C10 (KIOL-850C10 adds support for Windows 10 Operating System and installs NI-VISA Runtime 17.5 and NI-ICP 17.0. This release replaces previous versions of KIOL-850B07, KIOL-850C02, KIOL-850C03, KIOL-850C04, KIOL-850C05 …

Part Number: KIOL-850C10
Application
2700 Firmware Version B11. Use only with version B01 or higher.
2700 Firmware Version B11 - use only with version B01 or higher. Updated to correct problems with relative timestamp has overflows, adding channels to a scan list, averaging filter.

Part Number: 2700-803B11
Firmware
2701 Firmware Revision B03
"2701 FIRMWARE RELEASE PACKAGE version B03 for use to upgrade instruments with version B firmware only. Do not install on instruments with version A, C or D firmware. Upgrade by using the latest Keithley Flash Wizard Utility."

Part Number: 2701-FRP-B03
Firmware
KickStart Instrument Control software Version 1.9.8 (use with HRMA app)
Easy to use instrument control software Required for use with KickStart’s High Resistance Measurement App (HRMA) For all other apps, consider KickStart 2 as a replacement Compatible with Windows 7, Windows 8 and Windows 10.

Part Number: KICKSTART-1.9.8
Application
Model 2701 Firmware Revision D05
Model 2701 FIRMWARE RELEASE PACKAGE VERSION D05 (NOTE: This firmware applies to units with D0x firmware only. Do not attempt to upgrade units with older A0x, B0x or C0x firmware)

Part Number: 2701-800D05
Firmware
Keithley I/O Layer - version C07 (Windows 8, 7, Vista, and XP Compatible)
Keithley I/O Layer version C07 (KIOL-850C07 adds a change to only send the :syst:rem command to RS-232 connections This release replaces previous versions of KIOL-850B07, KIOL-850C02, KIOL-850C03, KIOL-850C04, KIOL-850C05, KIOL-850C06). This version …

Part Number: KIOL-850C07
Application
2750 FIRMWARE VERSION A15 RELEASE PACKAGE
Contains the Customer Release Notes as well as the flash upgrade image file to be used with Flash Wizard.

Part Number: 2750-FRP-A15
Firmware
Models 2700/2701/2750 Integra Up And Running TestPoint Runtime Software Rev. B03 (43Mb)(UNSUPPORTED)
Integra Up&Running TestPoint Runtime Software for the 2700 and 2750. Includes KE2700 Instrument Driver and Keithley I/O Layer. Rev. B03 08/02/05 6/13/02: revision A02.0.2 8/21/02: Adds support for 2701. revision now B01 7/2/03 : adds support for …

Part Number: TESTPOINT27XX-B03
Application
2750 Firmware A14 and Release Notes
This zip file contains the Flash Wizard to upgrade the Model 2750 to firmware revision A14 and Release Notes.

Part Number: 2750-801A14
Firmware
2700 Firmware Upgrade version B09 and Release Notes- use only with version B01 or higher
Flash Wizard to upgrade 2700 to firmware version B09. May only be used on Rev B or higher. Adds support for 7710 switch module.

Part Number: 2700-804B09
Firmware
2700/2750 TestPoint 3.3 Library - Legacy (non-IVI)

Part Number: 2700-TP-LIB-3.3
Driver
2700/2701/2750 IVI Driver for Visual Basic (VB6, VB.Net), VC/C++, LabVIEW (LV) & LabWindows/CVI Rev. C03 - Requires Installation of Keithley I/O Layer (KIOL-850C06 or higher) (Windows 7, Vista, XP and Win2K Compatible)
IVI style multi-platform Instrument Driver for the 2700, 2701 and 2750. May be used with LabView 5.1 or later, or LabWindows CVI 5.5 or later, VB6, VB.net. Version is 2700-852C03 (previous version was 2700-850C02). Now supports Windows 7, Vista, XP …

Part Number: 2700-852C03
Driver
Flashwizard version C12 (Windows 7, Vista, XP, Win2K, NT, ME, 98 Compatible)
Flashwizard executable version C12 (Windows 7, Vista, XP, Win2K, NT, ME, 98 Compatible)

Part Number: FLASH-WIZARD-C12
Firmware
2700/2701/2750 IVI Driver for Visual Basic (VB6), VC/C++, LabVIEW (LV) & LabWindows/CVI Rev. B01.4 - Requires Installation of Keithley I/O Layer (KIOL-850B04 or older) (Win-98, Win-NT, and Win-ME only)
IVI style multi-platform Instrument Driver for the 2700 and 2750. May be used with LabView 5.1 or later, or LabWindows CVI 5.5 or later. 08-21-02: Adds support for 2701, fixes bugs. New part number and version. 2700-852B01 Version B01. 4-30 …

Part Number: 2700-852BB01.4
Driver
2750 Firmware upgrade version A13
Flash wizard to upgrade 2750 to A13 firmware rev. Self extracting winzip exe file.

Part Number: 2750-801A13
Firmware
Model 2700 Multimeter/Data Acquisition System Specifications
Model 2700 Multimeter/Data Acquisition System Specifications Rev. K.

Literature Number: SPEC-2700K
Specification
Understanding Control Systems and Communications for Today's Automobiles
Fact Sheet
Model 2700/2701/2750 Series/Integra Series Modules Selector Guide
2009 Catalog page for Selector Guide for Plug-In Modules for 2700, 2701, 2750 Integra Mainframes. Includes Models: 2700, 2701, 2750, 7700, 7701, 7702, 7703, 7705, 7706, 7707, 7708, 7709, 7710, 7711, 7712
Product Selector Guide
Model 2700 Brochure
A datalogger,a DMM,and a measurement/control system at the price of a PC plug-in card. It ?s a unique multipoint measurement and control solution that combines in one half-rack unit the functionality and high channel count of a datalogger with the …
Brochure
Ensuring the Accuracy and Cost-Effectiveness of Temperature Measurement Systems
This applications brief examines how to evaluate the advantages and disadvantages of various sensor types and the instrumentation options available so that sensor outputs result in accurate and reliable measurements.

Literature Number: 1KW-61407-0
Application Note
Model 2750 Multimeter/Switch System Specification
Model 2750 Multimeter/Switch System Specification Rev. J.

Literature Number: SPEC-2750J
Specification
Making Precision Low Voltage and Low Resistance Measurements E-Handbook
Fact Sheet
Understanding Power Testing Applications for Today's Automobiles
Brochure
Low Voltage/ Low Resistance Measurements
Product Selector Guide
Problem: Errors in Low Resistance Measurements
Technical Article
Synchrotron High Speed Magnetics Monitoring
This version includes the product side bar.
Technical Article
RF/Microwave Switching Systems Subtleties: Achieving the Performance You Need
Technical Article
Applications Guide - Techniques for Multi-Channel Testing and Data Acquisition
Fact Sheet
2700 and 2750 Software Selector Guide
2700 and 2750 software Technical Data Sheet and selector guide
Brochure
New Test Realities for Evolving FPD Technologies
Job #2401
Whitepaper
E-Handbook to Understanding Electrical Test and Measurement
Fact Sheet
Power Testing Applications for Today's Automobiles
Brochure
Problem: Noisy Readings in Low Resistance Measurements
Technical Article
Switch to 42 Volt Automotive Systems Brings Challenges and Opportunities
.
Technical Article
Solutions for Production Testing of Connectors
Application Note
The Secret to Thermocouples - Mind the Metallurgy, and All Else Will Follow
Imagine an electronic sensor technology that?s simple, cheap, reliable, and 200 years old. Look no farther than the popular thermocouple. In the early 1800s, Thomas Seebeck discovered that the junction of two metals generates a voltage that depends …
Technical Article
Digital Multimeters Comparison Table
Table comparing DC volts, AC volts, ohms, DC amps, AC amps, and other measurement capabilities of Keithley and Tektronix DMMs.

Literature Number: 1KW-61264-2
Product Selector Guide
Digital Multimeters (DMM) Selector Guide
Complete guide to selecting Tektronix and Keithley digital multimeters (DMMs) including features, benefits, measurement capabilities, and comparison of models.

Literature Number: 1KW-61350-1
Selection Guide
High Reliability Power Supply Testing
The reliability of a power supply must match or exceed the rest of the system in which it is installed. Generally, this requires fast production testing that accurately characterizes key parameters.
Technical Article
Fundamentals of HALT/HASS Testing
The rapid growth in many electronic sectors has required an increase in production of critical sub-systems, such as switching power supplies, DC-to-DC converters, telecommunication devices, and related assemblies. Frequently, these sub-systems …
Whitepaper
Integra Series Software Brochure
Software brochure describing Keithley start-up sofware solutions for the integra series.
Brochure
DAQ Data Acquisition Primer: An Introduction to Multi-Channel Measurement Systems
This data acquisition primer offers tips and techniques for making multi-channel measurements in a variety of applications.  Learn about: Relay types and switch card options for making multi-channel measurements Switch card configuration …

Literature Number: 1KZ-61325-0
Primer
Keithley's Switching Systems - Switch and Control Solutions for DC, RF, and Light
This is the brochure for switching and control solutions. Job No. 1582
Brochure
How to Program an Instrument to Assert SRQ on the GPIB Bus
Application Note
How to control multiple Integra Series Products with ExceLINX-1A
Application Note
High Reliability Power Supply Testing
Application Note
Keithley’s DAQ6510 6½-Digit Data Acquisition and Logging Multimeter System
With the new DAQ6510, you can achieve everything from better operation, wider measurement range, and significantly reduced test time. Please check the comparison with the existing model 2700/2701 in PDF.

Literature Number: 1KW-61521-0
Fact Sheet
Test Methods for Automobile Communication and Control Systems
Fact Sheet
E-Guide: High Performance DMMs for Single- and Multi-Channel Applications
Fact Sheet
2700 XLINX Startup Software (Version 2.1) - Legacy (UNSUPPORTED)
Keithley Instruments Model 2700 Startup Software

Part Number: XLINX-V2.1
Model 2750 Multimeter/Switch System
2007 Catalog page for Model Model 2750 Multimeter/Switch System.
Datasheet